Getting My Dp50rb To Work
Getting My Dp50rb To Work
Blog Article
one.two.two Warning Labels Warning Labels Meaning Be sure to cautiously look at this manual before use product. The following labels certainly are a. Never place the product on a sloped surface. Otherwise the accessible once the process system may slide, causing own injury or maybe the system works Together with the mobile malfunction.
.. Website page 161 The indicator about the printer Problems happen once the adapter turns orange, and also the printing printer adapter operates. Disconnect and hook up the fails. electric power adapter, electrical power on the printer adapter yet again, and confirm if the printing is usual soon after 1 minute. Webpage 163: Electrical Security Inspection
Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat depth login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.
Permits use of various scanned angles to form just one picture, causing Improved distinction resolution and enhanced visualization
The chapter supplies the method to validate primary operate and performance of products. This is often only useful for reference, not preventive execution. Functionality examining and tests of this section shall be completed by Mindray assistance engineers plus the consumer alongside one another. Webpage sixty six: Normal Exam
Operate: Over the back again-finish of the principle board, a special keep an eye on IC is used to monitor signal voltages and clock battery electric power that are offered to the primary board by the key device box ability supply module.
Effectiveness Take a look at five.5.one Check Process Resolution Detection depth Geometric Position Accuracy Blackout location check Record the Examination photos 5.five.2 Check Articles The image employed Here's only for reference, stick to the graphic impact in the actual Be aware: scenario. Requirements: Display screen: set the distinction and brightness on the medical application price (or perhaps the default position) Operation ecosystem: dim place, simulating the scientific software atmosphere. Web site seventy six In condition the transverse resolution screening targets are horizontally shown, document the minimal distance of two targets that could be Obviously acknowledged. Repeat the operation earlier mentioned for your transverse resolution tests targets at other depths. As shown in figure underneath. Axial resolution ... Website page seventy seven When using the convex probe, hold the transverse resolution testing targets to notice: be exhibited close to the midline. When employing a linear probe with steer perform, will not activate the steer function when conduct the transverse resolution examination. Zoom inside the area where the targets Positioned if necessary. The diameter with the goal position at a specific depth is equivalent for the transverse resolution on the depth. Web site 78 five.
5.2.three Geometric positioning precision Longitudinal geometric positioning precision Test Action: Do changes as the way in which in testing the utmost depth. Record the gap by 20mm Just about every segment to the longitudinal targets line using the measurement caliper; Decide on the value with the best mistake (to 20mm), estimate the precision using the components under The measurement caliper needs to be positioned in the upper fringe of the focus on, Notice:... Page 79 Transverse geometric positioning precision Exam Action: Address the scan floor in the phantom with water or few gel, gently Get in touch with the probe With all the scan surface area Adjust the depth, earning the transverse targets to get exhibited in the image. Alter the main target stage to get posited beside the transverse targets (the conventional is not crystal clear) Alter parameters like acquire, TGC, earning Just about every transverse targets being clearly shown. Site eighty five.5.two.four Blackout Place Take a Dp50rb login look at Phase: Include the scan area on the phantom with drinking water or couple gel, Carefully contact the probe Together with the scan floor Regulate the depth at a decrease benefit, and set the focus at the nearest place to the scan area. Decrease the worth of parameters like AP, Attain until eventually the history noise just might be witnessed. Webpage 81: Software Improve And Maintenance
Cookies are essential to the proper operating of a website. To transform your expertise, we use cookies to recall log-in particulars and provide protected log-in, obtain figures to improve site features, and supply information personalized for your interests.
Assist 4D probe; identify the probe by way of the ID code; switch the 4D push sign through the electrical relay for making the 4D probe function Ordinarily. 4.2.2 Principal board The main board might be divided into two sections: entrance-conclude of the key board and back again-finish of the main board.
Webpage 45 Return “Printer Services” page, Choose the corresponding company with the printer list and improve the services. The program integrates motorists of HP printers, right after HP printers are linked, drivers are going to be set up quickly (about 10s).If automobile installation fails, icon will display on the appropriate reduced corner of your screen to warn you that guide set up is necessary. Website page forty six: Network Preset
Mindray’s new generation of black & white ultrasound system, DP-50 Expert, is supplied with Sophisticated imaging systems making it possible for deeper penetration and quicker graphic acquisition with increased resolution.
Minimize off cable ties connecting the most crucial unit about the Exhibit by diagonal slicing pliers, then pull out the corresponding cable plugs.
Observe: On the watch, the brightness adjustment will come right before distinction. Following readjusting the observe’s distinction and brightness, regulate all preset and peripheral configurations.